L-Cor 6000 |
| Measuring range |
36 kg/h to 61 200 kg/h |
| Flow accuracy |
± 0.15 % ± ZS* |
| Flow repeatability |
± 0.075 % ± ½ ZS* |
| Density range |
500 kg/m3 to 1,000 kg/m3 or 700 kg/m3 to 1,300 kg/m3 or 1000 kg/m3 to 1,500 kg/m3 |
| Density accuracy |
± 2 kg/m3 |
| Nominal diameter |
1/2” to 3” |
| Ambient temperature |
- 40 °C to +55 °C |
| Process temperature |
- 40 °C to +130 °C |
| Process pressure absolute |
According to flange specification |
| Process connection |
ASME B16.5 Class 150 Tri-clamp ISO 2852 |
| Wetted parts |
Titanium alloy |
| Approvals for potentially explosive atmospheres |
ATEX, IECEx, CSA (C-US), NEPSI (CCC) |
| Outputs |
2x analog, 2x pulse (frequency), 1x status output |
| Inputs |
1x status input |
| Digital communication |
Bell 202, Modbus RTU (RS-485), Profibus PA, Fieldbus |
| Transmitter version |
Integrated, separately mounted, mounted in control cabinet |
| Certifications |
EHEDG |
*Accuracy valid at reference conditions. ZS = Zero stability error = (Zero stability)/(Flowrate at the moment) x100%