Specifications:
- Construction
- Cabinet of 5 mm zinc anneal steel lined with insulating firebrick.
- Backed with insulating fire brick.
- Muffle Dimensions
- 25 Place—400mm high x 600mm wide x 680mm deep
- 50 Place—400mm high x 1200 mm wide x 680mm deep
- Flame Supervision
- LPG : Landis & Gyr LME 44 Flame Controller & U.V. Cell
- NG & Diesel : Landis & Gyr LFL1.635 & Flame Controllers
- Door Operation
- 25 Place— Counter-balanced, rising
- 50 Place: Pneumatic rising. Operated by foot control
- Temperature Control
- Electronic, Automatic control 1200oC, Type “K” Thermocouple
- Electrical Requirements
- The furnace is fitted with a 10 Amp single phase cord and plug top.
- Electrical load: 5 Amps
- Approximate overall dimensions with door open
- 25 Place—1960mm high x 1320mm wide x 1450mm deep
- 50 Place—1960mm high x 1790 mm wide x 1450mm deep
To contact ALSTO about Fusion Furnace | Gas (LPG & NG) and Diesel (25 place and 50 place) use Get a quote.